{"product_id":"protectowire-phsc-172-epc-linear-heat-detection","title":"Protectowire PHSC-172-EPC Linear Heat Detection","description":"\u003ch2\u003eProtectowire, PHSC EPC 172°F 78°C Brown Jacket Linear Heat Detection\u003cbr\u003e\n\u003c\/h2\u003e\u003cdiv class=\"ths-mfr-data\"\u003e\n\u003cp\u003eThe Protectowire PHSC-172-EPC is a digital, fixed-temperature linear heat detector cable that alarms at 172°F (78°C) and has a brown Type EPC jacket. When heat at any point along the cable reaches the rated temperature, the heat-sensitive polymer on its two twisted steel conductors gives way, the conductors short and the alarm is initiated. The flame-retardant vinyl EPC jacket is intended for interior commercial and industrial use, with low moisture absorption, resistance to many common chemicals and low-temperature flexibility. JEM Systems Canada supplies it with shipping across Canada.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFixed-temperature digital linear heat detector, alarm temperature 172°F (78°C)\u003c\/li\u003e\n\u003cli\u003eMaximum ambient (installation) temperature 130°F (54°C); minimum -40°F (-40°C)\u003c\/li\u003e\n\u003cli\u003eType EPC (extruded polyvinyl chloride), flame-retardant vinyl outer jacket\u003c\/li\u003e\n\u003cli\u003eTwo steel conductors individually insulated with a heat-sensitive polymer and twisted together\u003c\/li\u003e\n\u003cli\u003eDetects heat at any point along its length; no minimum heated length and no calibration for ambient changes\u003c\/li\u003e\n\u003cli\u003eUL\/cUL listed spacing up to 50 ft (15.2 m)\u003c\/li\u003e\n\u003cli\u003eCan share an initiating circuit with other initiating devices such as pull stations, heat and smoke detectors\u003c\/li\u003e\n\u003cli\u003eFM Approved for Class I, II and III, Division 1 hazardous areas when used with suitably approved Protectowire control equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"ths-spec-table\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAlarm temperature\u003c\/th\u003e\n\u003ctd\u003e172°F (78°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum ambient temperature\u003c\/th\u003e\n\u003ctd\u003e130°F (54°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMinimum ambient temperature\u003c\/th\u003e\n\u003ctd\u003e-40°F (-40°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOuter jacket\u003c\/th\u003e\n\u003ctd\u003eEPC (extruded polyvinyl chloride), flame-retardant vinyl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConductors\u003c\/th\u003e\n\u003ctd\u003eSteel (PHSC type)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaximum voltage rating\u003c\/th\u003e\n\u003ctd\u003e30 VAC, 42 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConductor resistance\u003c\/th\u003e\n\u003ctd\u003e0.185 ohms\/ft (0.607 ohms\/m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMinimum bend radius\u003c\/th\u003e\n\u003ctd\u003e2.5 in (6.4 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDiameter\u003c\/th\u003e\n\u003ctd\u003eNominal 5\/32 in (4 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUL\/cUL max. listed spacing\u003c\/th\u003e\n\u003ctd\u003e50 ft (15.2 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFM max. listed spacing\u003c\/th\u003e\n\u003ctd\u003e30 ft (9.1 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eCompatible With\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProtectowire PIM-530, PIM-230 and PIM-120 interface modules\u003c\/li\u003e\n\u003cli\u003eProtectowire FireSystem control panels\u003c\/li\u003e\n\u003cli\u003eCompatible fire alarm control panel initiating circuits\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDocuments \u0026amp; Downloads\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/protectowire.com\/wp-content\/uploads\/DS-6592AC-Protectowire-LHD.pdf\" target=\"_blank\" rel=\"noopener\"\u003ePHSC \u0026amp; PLR Linear Heat Detector Data Sheet (DS-6592)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/protectowire.com\/wp-content\/uploads\/DS-8476V-0126-LHD-temp-chart.pdf\" target=\"_blank\" rel=\"noopener\"\u003eLinear Heat Detector Temperature Ratings Chart (DS-8476)\u003c\/a\u003e (Selection Chart)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/protectowire.com\/wp-content\/uploads\/DS-7736W-0725-PHSC-installation.pdf\" target=\"_blank\" rel=\"noopener\"\u003ePHSC Linear Heat Detector Important Installation Information (DS-7736)\u003c\/a\u003e (Installation Sheet)\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/protectowire.com\/wp-content\/uploads\/2018\/06\/Protectowire_Installation_Manual-Man-2001-1.pdf\" target=\"_blank\" rel=\"noopener\"\u003eProtectowire Installation Manual (MAN-2001)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Protectowire","offers":[{"title":"Default Title","offer_id":67789568180500,"sku":"PHSC-172-EPC","price":1690.9,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0705\/0516\/9172\/files\/protectowire-linear-heat-detection-default-title-protectowire-phsc-172-epc-linear-heat-detection-37780095402208.webp?v=1792904365","url":"https:\/\/jemsystems.ca\/products\/protectowire-phsc-172-epc-linear-heat-detection","provider":"JEM Systems Canada","version":"1.0","type":"link"}